Attach the UWP by hanging it on the top hook of the Junction Box Adapter and then snapping the bottom of the UWP in place. 2 compressors and 0 stage of backup heat. 7. The Honeywell ProSeries thermostats are the new smart thermostats for our homes. If there is one wire connected to the R terminal and one wire connected to the Rc terminal, set the slider to the down position (2 wires). NOTE: Available Fan modes vary with system settings. In Installer Setup, set changeover valve to O (for cool changeover) or B (for heat changeover). In Installer Setup, set system type to 2Heat/2Cool Conventional. Press the Mode button to cycle to the next available System mode. Copyright © 2020 Resideo Technologies, Inc. Honeywell Home is a trademark of Honeywell International Inc. used under license to Resideo Technologies, Inc. Do not overtighten. From smart WiFi thermostats with room sensors and humidification control, to programmable and non-programmable thermostats, Honeywell Home products meet a variety of needs. See Figure 3. Insert R and C wires into designated terminals for primary AC power (C terminal is optional if batteries are installed, but it is recommended). Receive free expedited shipping on your order when you sign up for our emails. Drill holes at marked positions, and then lightly tap supplied wall anchors into the wall using a hammer. Wiring heat pump systems Shaded areas below apply only to TH6320U/TH6220U or as otherwise noted. Once verified the control panel will take the appropriate action. The upstairs gets unbareingly hot in the summer; and my husband cannot get the thermostat below 70. See THP9045 instructions for more information. PR-MINI-PRO reader, 5 inch read range, 6" x 1.7" (152 x 43mm) size 12VDC 60ma power, -22 to 150° F (-30 to 65° C). The most commonly used terminals are shaded. 06-16 Printed in U.S.A. Insert AA batteries for primary or backup power. Level and mark hole positions. If there is only one R wire, and it is connected to the R, Rc, or RH terminal, set the slider to the up position (1 wire). Reliable, Pro Series readers use an advanced signal processing technique to read the PX-4-H proximity cards. See Figure 1. Push excess wire back into the wall opening. From smart WiFi thermostats with room sensors and humidification control, to programmable and non-programmable thermostats, Honeywell Home products meet a variety of needs. Your email address will not be published. Secure, Pro Series readers are designed to provide protection against reader tampering. CAUTION: MERCURY NOTICE If this product is replacing a control that contains mercury in a sealed tube, do not place the old control in the trash. In ISU set Heat system type to Radiant Heat. Separate the Junction Box Adapter from the Cover Plate. CAUTION: EQUIPMENT DAMAGE HAZARD Compressor protection is bypassed during testing. A smart thermostat can make your living more comfortable and save a lot on the monthly bill consumption. Mount the Junction Box Adapter to the wall or an electrical box using any of the eight screw holes. Move R-Slider Tab on UWP to the R setting. NOTE: Slider Tabs for U terminals should be left in place for T6 Pro models. Positive Reader ID, A LED indicator on the Pro Series readers visually confirms a successful read. Your email address will not be published. Low Power Consumption, all readers use low power 12 or 24 VDC for extended reader operation while operating on backup batteries. In ISU set Heat system type to Heat pump. PR-MINI-PRO reader, 5 inch read range, 6" x 1.7" (152 x 43mm) size 12VDC 60ma power, -22 to 150° F (-30 to 65° C). Required fields are marked *. Northern Computers' Pro Series proximity card readers easily replace other card reader technologies including Wiegand, magnetic stripe, barium ferrite, and others. Cards may also be produced with company logo, or have the users photograph and cardholder information printed or laminated onto the card. See Figure 2. User Manuals, Guides and Specifications for your Honeywell pro Series Thermostat. Position the UWP on wall. Take control of your home comfort and save on energy costs with a range of Honeywell Home thermostats. Questions about your Manual? Systems that accept these types of cards and readers will accept Northerns' Pro Series readers. Warranted, Pro Series readers are warranted for two (2) years from date of shipment. 1 compressor and 1 stage of backup heat. Or when you need to cover paint gap from old thermostat. Before starting, turn the power off at the breaker box or switch. In fact the reader may be mounted behind a window or most non-metallic building materials. We live in a split level duplex. 3. honeywell pro Series Professional Install Manual (45 pages) Smart Thermostat. Single-stage Programmable Thermostat Support, Pro 2000 Horizontal Programmable Thermostat Support. Align the UWP with the thermostat, and push gently until the thermostat snaps in place. Positive Reader ID, A LED indicator on the Pro Series readers visually confirms a successful read. Honeywell pro Series Manuals & User Guides. Use the K terminal in place of the Y and G terminals on conventional or heat pump systems to provide control of the fan and the compressor through a single wire—the unused wire then becomes your common wire. In ISU set Heat system type to Heat pump. See Figure 7. Learn more about Resideo's response to COVID-19 >, See current discounts, promotions and bundles, Get more back and more out of your products. Cycle through the modes until the required Fan mode is displayed and leave it to activate. To send another card read to the control panel, the card must be removed from the general area of the reader and be presented again. 1H/1C System (1 transformer) R Power [1] Rc [R+Rc joined by Slider Tab] [2] Y Compressor contactor C 24VAC common [3] W Heat relay G Fan relay, Heat-only System R Power [1] Rc [R+Rc joined by Slider Tab] [2] C 24VAC common [3] W Heat relay, Heat-only System (Series 20) [5] R Series 20 valve terminal “R” [1] Rc [R+Rc joined by Slider Tab] [2] Y Series 20 valve terminal “W” C 24VAC common [3] W Series 20 valve terminal “B”, Heat-only System (power open zone valve) [5] R Power [1] Rc [R+Rc joined by Slider Tab] [2] W Valve C 24VAC common [3], 1H/1C System (2 transformers) R Power (heating transformer) [1] Rc Power (cooling transformer) [1] Y Compressor contactor C 24VAC common [3, 4] W Heat relay G Fan relay, Heat-only System with Fan R Power [1] Rc [R+Rc joined by Slider Tab] [2] C 24VAC common [3] W Heat relay G Fan relay, Cool-only System R Power [1] Rc [R+Rc joined by Slider Tab] [2] Y Compressor contactor C 24VAC common [3] G Fan relay, 2H/2C System (1 transformer) [6] R Power [1] Rc [R+Rc joined by Slider Tab] [2] Y Compressor contactor (stage 1) C 24VAC common [3] W Heat relay (stage 1) G Fan relay W2 Heat relay (stage 2) Y2 Compressor contactor (stage 2).

Great Sandy Desert Facts, Lg Classic Phone, Grafana Sqlite To Mysql, 653cc Subaru Engine Reviews, Found Footage 3d 123movies, Easton Axis 5mm Match Grade, Guinea Pig Age Chart, Steve Mcnair Net Worth,

Print Friendly, PDF & Email

Preferències de les cookies

Cookies tècniques

L'informem que la navegació a la nostra pàgina web no requereix necessàriament que l'usuari permeti la instal·lació de les cookies, no obstant això, sí podria ser que la navegació es veiés entorpida. Per aquest motiu, si vostè desitja rebutjar la instal·lació de cookies o configurar el seu navegador per tal de bloquejar-les, i en el seu cas, eliminar-les, a continuació li oferim els enllaços dels principals proveïdors de navegació on podrà trobar la informació relativa l'administració de les cookies:

PHPSESSID, Real-accessability, Pll-language

Analitics

Les cookies de tercers que utilitza aquest lloc web són:

_ga (Google Analytics) El seu ús és diferenciar usuaris i sessions. Caducitat 2 anys

_gat (Google Analytics) El seu ús és limitar el percentatge de sol·licituds rebudes (entrades a la website). Caducitat 1 minut

_gid (Google Analytics) El seu ús és diferenciar usuaris i sessions. Caducitat 24h

Google Analytics